Automatic Power Factor Controller

SYCON 66xx APFC

Intelligent KVAR based switching

Display of short fall / Excess. KVAR on LCD

Display of THD & 3rd to 13th harmonics

Capacitor stage indication by LED

Available in DG model

Available in HT-CT Sensing

SYCON 66xx - ss APFC

Intelligent KVAR based switching

Multiple capacitor switching for faster achievement of PF

Ideal for thyristor modules

RS-485 port available

Display of KW, KVA, KVAR on LCD

Adjustable capacitor time delays

Alarms (optional)

SYCON 55xx - ss APFC

Intelligent KVAR based switching

Bright 7 - segment LED display

Display KVA, KW, KVAR, Shortfall KVAR

Adjustable CT primary & Target PF

Capacitor stage indication by LED

SYCON 55xx APFC

FIFO Switching

Two point PF setting

Display of two digit PF with lag ad lead indications

SYCON 66PK APFC

Available in 12 steps

Per Phase Compensation

Large LCD Display ( 20*4 characters )

Display of: Short Fall (RYB), Voltage (RYB), Current (RYB), Kw (RYB), Kvar (RYB), Kva (RYB)

SYCON 55xx2D APFC

FIFO Switching

Two point PF setting

Available in 4, 6 & 8 steps

Small size ( 96*96 )

Maximum Demand Controller

SYCON 4600 Intelligent Load Manager (KVA/KW)

1 Alarm 3 Trip Model

Display of Average, PF, KW, KVA, KVAR, Frequency

Selectable display of present & previous demand

Adjustable integration time 15min OR 30min

Available in 3 phase 3 wire OR 3 phase 4 wire

RS-485 port with MODBUS protocol

SYCON 4400 Maximum Demand Controller (KVA/KW)

1 Alarm 3 Trip Model

Display of Average KVA demand, voltage & current

Selectable display of present & previous demand

Adjustable integration time 15min OR 30min

Available in 3 phase 3 wire OR 3 phase 4 wire

RS-232 port

SYCON 4300ss Intelligent Load Manager (KVA/KW)

1 Alarm 1 Trip Model

Display of Average KVA demand, voltage & current

Selectable display of present & previous demand

Adjustable integration time 15min OR 30min

Available in 3 phase 3 wire OR 3 phase 4 wire

Protection Relay

SYCON 2220 Intelligent Motor Protection Relay

Display of thermal current

Settable inverse time curves

Alarm for tripping

Ultra compact size

Protection against thermal overlaod, unbalance phase failure, reverse phase, stalling, earth leakage, undercurrent

SYCON 2110 Motor Master Relay

Advance microcontroller technology

Overload protection with inverse time characteristics.

Protection against unbalance, single phasing, reverse phase overload

Settable overload current and time

Visual indication of S.P.P and overload

Ultra compact size

SYCON 77** Earth Leakage Relay (Panel Mounting)

Solid State

Wide operating current range

Low Power Consumption

Variable Current & Time Setting

Fault Indication

Test and Reset facility

Ideal for compliance to IE rule 61-A

SYCON 7701/02/03 Earth Leakage Relay (Din Rail Mounting)

Solid State

Wide operating current range

Low Power Consumption

Variable Current & Time Setting

Fault Indication

Test and Reset facility

Ideal for compliance to IE rule 61-A

SYCON 7721/22/23 Earth Leakage Relay with Display

Solid State

Wide operating current range

Low Power Consumption

Variable Current & Time Setting

Fault Indication by LED

Test and Reset facility

SYCON 7800 Earth Fault Relay

Solid State

CT operated

Fault Indication

Test and Reset facility

Current range 10% to 80% (in steps of 10%)

Tripping time 0.15 sec to 3 sec.

Digital Panel Meters

SYCON 9900-P Digital Multifunction Meter

Large 16 x 2 LCD

Display of voltage, current, PF, KW and KWH, frequency

Password protection for setting

Site adjustable primary and secondary currents of CT

SYCON 9900-Q Digital Multifunction Meter

Large 16 x 2 LCD

Display of voltage, current, PF, KW-T, KVA-T, KVAR-T, KWh and frequency

Password protection for setting

Site adjustable primary and secondary currents of CT

SYCON 9900-R Digital Multifunction Meter

Large 16 x 2 LCD

Display of voltage, current, PF, KW(RYB), KVA(RYB), KVAR(RYB), KWh(RYB) and frequency

Password protection for setting

Site adjustable primary and secondary currents of CT

SYCON 9980 Digital Three Phase KWh Meter

16 X 1 large LCD

True RMS measurement

Reset and password protection for settings

Site settable CT primary upto 9000A.

SYCON 9991 Digital Voltage, Current and PF Meter

Display of Voltages (R-Y,Y-B,R-B,R-N,Y-N,B-N)

Display of currents (R,Y,B)

Display of power factor (three elements)

Display of frequency

SYCON 9900 Digital Multifunction Meter

Alphanumerical (20 x 4 character) backlight LCD display

More than 40 parameters including maximum demand and cumulative PF

Display of phase voltages, frequency, average and maximum demand

Password protection for setting

Site adjustable primary and secondary currents of CT

Panel Accessories

SYCON 6101/02/03/04 Thyristorised Capacitor Switching Modules

Switch ON at zero voltage

Switch OFF at zero current

Indication of Power ON, Capacitor ON

Protection & Indication of over voltage & current, thyristor open & short

Also available thyristor firing cards

SYCON Series Reactor

Output upto 100 KVAR

Rated Voltage 440V

Filter Factor 7%

Copper wound / Alumunium wound - iron core dry type

SYCON Current Transformer

Tape wound / Resin Cast

Class 1

Available 100 / 5 to 1000 / 5

CT Burden 5 VA to 15 VA

Get In Touch

  • 147, Lohar Chawl, Tawawala Bldg., 2nd Floor, Shop No. 25, Mumbai - 400002.
  • 022- 2206 5400 / 2205 8339
  • nayantrading@gmail.com

Copyright © 2016 All Rights Reserved By Nayan Trading Co. | Developed by BDM INFOTECH

whatsapp